No.
|
TECH 1 Display
|
Conditions for Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
12 |
DEADLOCK SWITCH
|
Ignition
OFF
All
doors closed
|
|
-
|
23
|
|
|
Turn
key 30° to the left in driver's door (unlock central locking)
|
OPEN
|
|
|
|
|
Turn
key 30° to the right in driver's door (lock central locking)
|
OPEN
|
|
|
|
|
Turn
key 60° to the right in driver's door (switch on anti-theft device)
Turn
key 30° to the left in driver's door
(unlock
central locking)
|
CLOSED 0V
|
|
|
Notes
on Trouble-shooting: |
Nominal
Value:
|
Cause
of Fault:
(If
nominal value is not attained)
|
· Release and disconnect wiring harness plug,
body and driver's door X11 |
OPEN
|
· Body wiring harness, short circuit to ground
from: K37/Ter. 23
to: X11/Ter. 7
· Control unit K37 defective
|
· Connect wiring harness plug X11/Ter. 7 in
body wiring harness to ground |
CLOSED 0V
|
· Body wiring harness, interruption
from: K37/Ter. 23
to: X11/Ter. 7
· Control unit K37 defective
|
· Connect wiring harness plug X11 again |
|
|
· Release and disconnect wiring harness plug
S41 |
|
|
· Connect wiring harness plug S41/Ter. 4 in
front door wiring harness to ground |
CLOSED 0V
|
· Front door wiring harness, interruption
from: X11/Ter. 7
to: S41/Ter. 4
· Control unit K37 defective
|
If nominal values are attained: |
|
· Switch S41 defective
|
|
|
|
|
|
|
|