CDLS, F0: DATA LIST - Test Step 26 KEY 1 PROGRAM ST > < CDLS, F0: DATA LIST - Test Step 24 PREV. KEY FUNC.

CDLS, F0:DATA LIST

 

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

25

KEY 1 STATUS

Ignition OFF

All doors closed

 

 

 

-

-

 

 

Press centre button of infrared transmitter 1

 

 

PROGRAMMED

 

 

 

 

Note:

 

Each time a button is pressed, the red LED in the infrared transmitter must illuminate (otherwise battery is flat).

 

 

 

 

 

 

 

If TECH 1 displays NOT PROGRAMMED, the actuated infrared transmitter is either not programmed or is not authorised for the vehicle.

 

 

 

 

 

 

 

Programming of infrared transmitter:

see F7:PROGRAMMING

 

The vehicle is supplied by the manufacturer with two keys whose infrared transmitters are programmed into the central locking control unit.

 

 

Therefore, NOT PROGRAMMED is usually displayed for the following parameters: KEY 3 STATUS to KEY 5 STATUS.

 

 

 

 

 

 

 