vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

CDLS, F5: ACTUATOR TEST - No. 04 S.ROOF/WINDOW > < CDLS, F5: ACTUATOR TEST - No. 02 UNLOCK/DEADL.

CDLS, Table 5, F5:ACTUATOR TEST

 

 

 

 

 

 

 

 

 

 

 

     from:    wiring harness plug K94/Ter. 15

     to:         ground

 

 

 

 

     from:    wiring harness plug K94/Ter. 15

     to:         ground

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

03

ARM/DISARM SIG

Ignition OFF

 

 

All doors closed

 

 

Electronic immobiliser switched off

(if necessary, switch off using centre button of infrared transmitter)

 

 

Turn key 30° to the left in driver's door (unlock central locking)

 

 

Press key F5 in the TECH 1 main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

 

 

 

 

21

 

 

 

After actuating the YES key again, an "arm" or "disarm" signal can be switched from the central locking to the anti-theft warning system:

 

 

 

 

 

 

 

Arrow key UP -> ARM

 

 

ARM     0V

 

 

 

 

 

Arrow key DOWN -> DISARM

 

 

The check is completed after a maximum of 30 s .

 

DISARM

 

 

 

Notes on Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Release and disconnect wiring harness plug K94 from anti-theft warning system control unit

 

 

·   Arm ATWS by pressing arrow key on TECH 1

 

 

·   Using multimeter, measure voltage

0 volts

·   Body wiring harness, interruption

     from:    K37/Ter. 21

     to:         X1/Ter. 85

 

 

·   Instrument panel wiring harness, interruption

     from:    X1/Ter. 85

     to:         K94/Ter. 15

 

 

·   Control unit K37 defective

 

 

·   Disarm anti-theft warning system by pressing arrow key on TECH 1

 

 

·   Using multimeter, measure voltage

5 volts

·   Body wiring harness, short circuit to ground

     from:    K37/Ter. 21

     to:         X1/Ter.85

 

 

·   Instrument panel wiring harness, short circuit to ground

     from:    X1/Ter.85

     to:         K94/Ter.15

 

 

·   Control unit K37 defective

 

 

If nominal values are attained:

 

·   Control unit K94 defective

 

 

 

 

CDLS, F5: ACTUATOR TEST - No. 04 S.ROOF/WINDOW > < CDLS, F5: ACTUATOR TEST - No. 02 UNLOCK/DEADL.