vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0: DATA LIST - Test Step 27 KEY 2 STATUS > < F0: DATA LIST - Test Step 25 KEY 1 STATUS

Central Door Locking System CDLS   Quick Check F0: DATA LIST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

26

KEY 1 PROGRAM ST

Only vehicles with infrared remote control:

Ignition OFF

All doors closed

 

 

-

-

 

 

Centre button of infrared key transmitter 1 depressed

 

IN RANGE

 

 

 

 

Note:

Each time a button is pressed, the red LED in the key infrared transmitter must illuminate (otherwise the battery is discharged).

If TECH 1 displays INVALID the key infrared transmitter 1 is not programmed or the wrong key infrared transmitter was actuated.

The vehicle is provided with two programmed keys by the manufacturer, i. e. INVALID is normally displayed for the following parameters KEY 3 STATUS to KEY 5 STATUS

 

 

 

 

 

 

If TECH 1 displays OUT OF RANGE the key infrared transmitter 1 must be synchronized as follows:

Ignition ON

Hold key infrared transmitter 1 very close to infrared receiver in interior lamp and press centre button several times within 10 s

If TECH 1 then does not display IN RANGE, key infrared transmitter 1 must be reprogrammed as specified in section 6.3.4.2.

 

 

 

 

 

 

 

 

 

 

 

F0: DATA LIST - Test Step 27 KEY 2 STATUS > < F0: DATA LIST - Test Step 25 KEY 1 STATUS