F0:DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Terminal
39
DISTANCE
Ignition ON
-
INTERN.
RANGE
Vehicle travelling at approx. 50 km/h
(31 MPH)
approximately the same as MID display (range)
Notes for Trouble-shooting:
Nominal Value:
Cause of Fault:
(If nominal value is not attained)
· Carry out RANGE CALIBR. according to table 6, F6:ADJUSTMENTS, follow instructions in TECH 1 precisely
- 3 litres
to + 3 litres
· MID defective