Beetle L4-1.9L DSL Turbo (ALH) (1998)
Evaporator Drain Tube: Testing and Inspection
9 - Evaporator water drain valve
- Checking see Fig. 1 below.
Evaporator Water Drain Valve, Checking
Fig. 1
-
Fold cover -1- in bulkhead insulation mat -3- upwards.
-
Remove drain valve -2- from opening in bulkhead -4-.
Check water drain valve as follows to ensure correct function:
-
The water drain valve must not be stuck together.
-
Insulation mat must not be deformed or damaged in the area of water drain valve.
-
The opening in the sealing cap of the water drain valve must point downwards.
NOTE: When the cover cap -1- is closed it must be flush with the insulation matting. If the cover cap -1- is pushed in too far the water drain valve
sealing cap -2- can become jammed.