volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 4184 > < Diesel Intake Air Shut-Off Valve|Locations
Page 1
background image

Diesel Intake Air Shut-Off Valve: Testing and Inspection
With Manufacturer's Scan Tool

Change-Over Valve For Intake Manifold Flap -N239-, Checking

Special tools

-

VAG 1390 Hand vacuum pump

-

VAG 1598/22 Test Box (MY 1999)

-

VAG 1598/31 Test Box (from MY 2000)

-

Fluke 83 multimeter

-

VW 1594 Adapter kit

-

Wiring diagram

Function, checking

-

Start engine and let idle.

-

Switch OFF ignition.

-

Observe position of lever on intake manifold change-over flap (using 2nd technician)
-

Intake manifold change-over flap must (after switching OFF ignition) close back and after approx. 3 seconds re-open.

If change-over does not occur, perform following checks

-

Check intake manifold change-over flap mechanics for freedom of movement by manually operating the rods by hand.

-

Check vacuum function of positioning actuator using VAG 1390 hand vacuum pump.

-

Check vacuum lines for correct connection.

If mechanical components OK

-

Check Intake Manifold Change-over Valve -N239-.

Test sequence

-

Disconnect -N239- harness connector.

With Manufacturer's Scan Tool|Page 4184 > < Diesel Intake Air Shut-Off Valve|Locations