volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 1084 > < With Manufacturer's Scan Tool
Page 2
background image

-

Disconnect -G62- harness connector (arrow).

-

Measure resistance between sensor terminals 1 + 3.

Specification see diagram
Scale A shows resistance values for temperature range 0 to 50 °C and scale B the values for temperature range 50 to 100 °C.

Examples:

-

30 °C corresponds to a resistance from 1500 to 2000 Ohms

-

80 °C corresponds to a resistance from 275 to 375 Ohms

With Manufacturer's Scan Tool|Page 1084 > < With Manufacturer's Scan Tool