Front Door Window Regulator: Testing and Inspection
Power Windows With Convenience System (Automatic Opening and Closing) With Force Limitation
Intervention (FLI)

Power Windows With Convenience System (Automatic Opening and Closing) With Force Limitation Intervention (FLI)

With the introduction of the comfort system power windows, the window regulators are equipped with automatic opening and closing features.

The switch for the front window automatic opening and closing functions is located in the driver's door controls. The switch for the driver's and front
passenger's door is equipped with a two level function.

If switch is pushed or pulled to the first detent the front windows open or close as long as the switch is being operated.

If the switch is briefly pressed or pulled to the 2nd detent the front windows will open or close automatically.

There are also switches in the front passenger's door.

All power windows are equipped with an excess force limitation system. Closing the window will be automatically terminated when an object blocks the
closing window path.

This is not valid when closing the window from the outside with an ignition key then the excess force limitation system is not operative.

Function of window regulator with ignition switched on 

Opening

Switch in driver's door
-

Press front section of switch down to 1st detent. The window will open as long as the switch is being operated.

-

Press of front switch briefly down to 2nd detent. The window will open automatically (automatic fully opening system).

-

If switch is operated again window will stop immediately.

Switch in front passenger's door
-

Press lower surface of switch. Window will open as long as switch is being operated.

Closing

Switch in driver's door
-

Pull front section of switch up to first detent. The window will close as long as the switch is being operated.

-

Pull front section of switch briefly up to 2nd detent. Window will close automatically (automatic fully closing system).

-

If switch is operated again the window will stop immediately. Switch in front passenger's door

-

Press upper surface of switch. The window will close as long as it's being operated.

Window regulator, function with ignition switched off

Window regulators can be operated for approx. 10 minutes after switching ignition off, as long as the driver's or front passenger's door have not been
opened.

The automatic closing function is inoperative when closing the front windows.

If the driver's or front passenger's door window meets excessive resistance or an object during the closing sequence (excessive force limitation) the
window will open again immediately.

In this case the window can only be closed again when the ignition is switched on.

The windows can be opened and closed from the exterior on vehicles with a central locking system. The key must be held in the lock or unlock
position.

Automatic opening and closing, adjusting

NOTE:  Automatic opening and closing features for the driver's and front passenger's windows do not function after disconnecting and reconnecting
vehicle battery.

To reactivate this feature after reconnecting the battery proceed as follows:
-

Lock vehicle from outside using driver's or passenger's door. Ensure doors and windows are closed completely.

-

Unlock vehicle and lock vehicle again at driver's or passenger's door. When doing this hold key for at least one second in the lock position.

The automatic opening and closing functions for the driver's and passenger's window is reactivated.

Difficulties In Window Upper Area With Force Limitation Intervention System (FlI), Overriding|Page 10418 > < Difficulties In Window Upper Area With Force Limitation Intervention System (FlI), Overriding