Beetle L4-2.0L (AEG) (2000)
See table for part number / EPROM levels of TCM's with corrected software.
Service:
This improper MIL illumination is caused by a 1CM programming design deficiency and cannot be corrected.
If a customer experiences automatic transmission related problems, along with the symptoms listed in this Technical Bulletin:
-
Perform the designated repair procedures as described in the Repair Manual CD-ROM Automatic Transmission: Automatic Transmission O1M -
On Board Diagnostics
DO NOT!
Replace a TCM for listed condition unless repair procedures (per diagnosis in Repair Manual) require replacement.