Vehicles with engine code AEG, AVH, AZG, item 3,

-

Vehicles with engine code BDC, item 1.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  

-

Generate readiness code.  See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If no malfunctions are detected in the wires and the resistance values are OK:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer Scan Tool

Intake Air Temperature Sensor, Checking

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551/1552 Scan Tool using VAG 1551/3 Adaptor cable

-

VAG 1598/22 Test Box

-

Fluke 83 multimeter

-

VW 1594 Adaptor kit

-

Wiring diagram

-

Chilling spray (commercially available)

NOTE:

If sensor or connecting wiring is faulty, the Engine Control Module operates with a substitute temperature of 19.5 °C.
Vehicles with engine code AEG; the Intake Air Temperature sensor is a part of the Mass Air Flow sensor G70 and cannot be replaced by itself.

Test sequence

-

Connect VAG 1551/1552 Scan Tool. See: Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble
Codes/Scan Tool Connecting  

-

Switch ON ignition.

-

Press 0 and 1 buttons to select "Engine Electronics" address word 01.

Indicated on display (example only)

06A906018AB Motronic M5.9.2 HS V06 ->
Coding 00000

WSC 00000

-

Press -> button.

Indicated on display

                                                                                                                      

Rapid data transfer 

HELP

Select function XX

-

Press 0 and 8 buttons to select "Read Measuring Value Block" function 08.

-

Press Q button to enter input.

Indicated on display

Read measuring value block
Input Display group number XXX

-

Press 0, 0 and 4 buttons to select "Display group 4."

-

Press Q button to enter input.

Indicated on display (1 to 4 = Display fields)

Read measuring value block 4      ->

1

2

3

4

-

Note Intake Air Temperature value in Display field 4.