volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Aging, Check|Page 3074 > < Diagram Information and Instructions|Page 3071
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor Aging, Check

Oxygen Sensor Aging, Check

Bank 1 Oxygen sensor 1

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551/1552 Scan Tool using VAG 1551/3 Adaptor cable

-

VAG 1788/10 Engine speed adjuster (or second technician)

Requirements

-

Engine Coolant Temperature must be 85 °C minimum Display group 04, Display field 3.

Functional check

-

Connect VAG 1551/1552 Scan Tool. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks", See: Computers and Control
Systems/Testing and Inspection 

-

Start engine and let idle

-

Press 0 and 1 buttons to select "Engine Electronics" address word 01.

Indicated on display (example only)

06A906018AB Motronic M5.9.2 HS V06 ->
Coding 00000 

WSC 00000

-

Press -> button.

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press 0 and 4 buttons to select Function 04: "Basic setting"

-

Press Q button to enter input.

Indicated on display

Basic setting
Input Display group number XXX

-

Press 0, 3 and 4 buttons to select "Display group 34."

-

Press Q button to enter input.

Indicated on display (1 to 4 = Display fields)

System in Basic setting 34 

->

1

2

3

4

-

Increase engine speed between 2200 and 2800 RPM and check specifications for Oxygen sensor aging before Three Way Catalyst (Display field
1 to 4).

NOTE:  To ensure that the exhaust gas temperature is within specification range during the test, the test RPM must be held for at least 1 minute.
Observe the Oxygen sensor control status in Display field 4.

Oxygen Sensor Aging, Check|Page 3074 > < Diagram Information and Instructions|Page 3071