volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Generic Scan Tool|Page 233 > < With Generic Scan Tool|Page 231
Page 1
background image

Electronic Throttle Control Module: Testing and Inspection
With Manufacturer's Scan Tool

Throttle Control Module, checking

NOTE:  If the Throttle Control Module is replaced, the new module MUST be matched to the Engine Control Module.  

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551/1552 Scan Tool using VAG 1551/3 Adaptor cable

-

VAG 1598/22 Test Box

-

Fluke 83 multimeter

-

VW 1594 Adaptor kit

-

Wiring diagram

Requirements

-

Throttle must be in Closed Throttle Position.

-

Throttle cable adjustment must be OK

-

Automatic transmission Range selector lever in "P" or "N"

-

A/C must be switched OFF, if installed

-

Cruise control system must function correctly, if installed.

Throttle Control Module, function

Components of the Throttle Control Module J338:

Throttle drive G186, Angle sensor 1 for Throttle drive G187, Throttle Position sensor G69 and Closed Throttle Position switch F60.

All adjustments are made using the VAG 1551 Scan Tool in Function 04: "Basic Setting."

If the Throttle Control Module loses power (e.g. disconnected) Throttle position will default to a mechanical setting. If the engine is warm, idle speed
will range between 1200 -1300 RPM.

If only the Throttle drive G186 lacks power, the Throttle valve will still move to the mechanical preset position, but because the Closed Throttle Position
switch F60 is still recognized; idle speed will be approx. 900 RPM which is achieved by retarding the ignition.

Closed Throttle Position switch F60, checking

Test sequence

-

Connect VAG 1551/1552 Scan Tool. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing
Diagnostic Trouble Codes/Scan Tool Connecting  

-

Switch ON ignition.

-

Press 0 and 1 buttons to select "Engine Electronics" address word 01.

Indicated on display (example only)

06A906018AB Motronic M5.9.2 HS V06 ->
Coding 00000 

WSC 00000

-

Press -> button.

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press 0 and 8 buttons to select "Read Measuring Value Block" function 08.

-

Press Q button to enter input.

Indicated on display

Read measuring value block
Input Display group number XXX

-

Press 0, 0 and 5 buttons to select "Display group 5."

-

Press Q button to enter input.

With Generic Scan Tool|Page 233 > < With Generic Scan Tool|Page 231