Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor (HO2S) -G130- After Converter, Checking

Heated Oxygen Sensor (HO2S) -G130- for Oxygen sensor after Three Way Catalytic (TWC) converter, checking

Special tools and equipment

-

VAG 1551 Scan Tool or VAG 1552 with cable VAG 1551/3

-

Test box VAG 1598/22

-

Hand multimeter VAG 1526 or multimeter VAG 1715

-

Adapter set VAG 1594

-

Wiring diagram

Check conditions

-

The battery voltage must be at least 11.5 V.

-

Fuel pump relay must be OK

Test sequence

-

Connect VAG 1551 Scan Tool ((VAG 1552). Start engine and select "Address word" 01 of engine control module. When doing this engine must
be running at idle speed. (Connecting scan tool and selecting engine control module See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Connecting VAG Scan Tool 1551/1552).

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press keys 0 and 8 for function "Read Measuring Value Block" and confirm entry with Q key.

Indicated on display

Read Measuring Value Block

HELP

Input display group number XXX

-

Press keys 0, 4 and 1 for "Display group number 41" and confirm entry with Q key.

Indicated on display: (1 to 4 = Display zones)

Read Measuring Value Block 41

->

1

2

3

4

-

Check Oxygen sensor heater resistance in display zone 3
Specification: 6.4 to 47.5 Ohm

-

Check Oxygen sensor heater status in display zone 4, display:
Htg.aC.ON, Htg.aC.OFF (alternating)

If the specifications are not attained:

-

Remove protective cover -arrows- and separate 4-pin connector (brown) to Oxygen Sensor (O2S) behind three way catalytic converter (TWC)
-G130-.