If the display in display zone 2 remains constantly at a value:

-

Continue check according to following table.

If B1-P2 OK appears in display zone 4 and the value displayed in display zone 3 is above 200 ms:

-

Check exhaust system for leaks.

If B1-P2 n.OK appears in display zone 4 and the value displayed in display zone 3 is above 1200 ms:

-

Press -> key.

-

Press keys 0 and 6 for function "End Output" and confirm entry with Q key.

-

Switch ignition off.

-

Carry out a test drive to remove possible residue on Oxygen sensor and repeat check.

Observe the valid safety precautions when carrying out a road test See: Powertrain Management/Fuel Delivery and Air Induction/Service
Precautions/Technician Safety Information.

If the specifications are again not attained:

-

Replace Oxygen Sensor (O2S) behind three way catalytic converter (TWC) -G130-.

NOTE:  If the Oxygen sensor voltage is OK and the delay period for the Oxygen sensor control after catalytic converter is still above 1200 ms even
after a test drive, this points to an aged Oxygen sensor before catalytic converter.

Checking basic voltage

-

Remove protective cover -arrows- and separate 4-pin connector (brown) to Oxygen Sensor (O2S) behind three way catalytic converter (TWC)
-G130-.