Remove positioning motor - A - from air intake shroud. 

Installing

-

Check shaft of recirculation door - C - before installing control motor - A -.

-

Set shaft - C - so that connecting element of control motor - D - can be inserted.

-

Insert control motor with connecting element - D - into shaft - C - and mounts at intake housing - B -. 

-

Install bracket - A -, take special care when doing this, that the bracket guide - B - is inserted correctly into intake housing mount - C - and bracket
is engaged in both retaining lugs - D - and - E -.