Extract refrigerant e.g. using A/C service station (VAS 6007A).

CAUTION!
There is a danger of ice-up.

Refrigerant leaks out if refrigerant circuit is not discharged.

Refrigerant must be extracted before opening refrigerant circuit. If refrigerant circuit is not opened within 10 minutes after extracting,
pressure may build up in refrigerant circuit by renewed evaporation. Extract refrigerant once more.

-

Remove screws - 1 - and disconnect refrigerant lines -  2 - from expansion valve.

-

Remove the bolts - 8 - and remove the expansion valve. 

5

O-ring

‹› 14 mm; 1.82 mm

‹› Coat with refrigerant oil when installing

6

O-ring

‹› 10.8 mm; 1.82 mm

‹› Coat with refrigerant oil when installing

7

O-ring

‹› 9.5 mm; 2.5 mm

8

Cylindrical combination bolt

‹› 5 Nm

Functions

‹› The expansion valve atomizes the streaming refrigerant and controls the flow quantity so that the vapor is gaseous only at the evaporator outlet,

depending on the heat transmission.