Workshop Repair Manuals

Volkswagen Workshop Manuals

[PREV PAGE] [NEXT PAGE]

volkswagen Workshop Repair Guides


Eos (1F7) V6-3.2L (BUB) (2008)

Heating and Air Conditioning > Refrigerant Pressure Sensor / Switch, HVAC > High Pressure Sensor / Switch, HVAC > Component Information > Technical Service Bulletins > Page 6202

Page 1
background image

High Pressure Sensor / Switch: Service and Repair

High Pressure Sensor

‹› High Pressure Sensor (G65) - 1 - may also be installed on a different side in the vicinity of the condenser, depending on the engine version.

‹› To loosen, counterhold the side of the refrigerant line with a suitable tool.

Removing

-

Remove lower engine cover.

-

Disconnect harness connector from high pressure sensor -  1 -.

-

Remove the high pressure sensor - 1 - from the refrigerant line connection.

Installing

Install in reverse order of removal.

-

Replace the O-ring.

To tighten, counterhold the side of the refrigerant line with a suitable tool.

Tightening specification 8 ± 1 Nm