Eos (1F7) V6-3.2L (BUB) (2008)
-
Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check
Start diagnosis
Function test
-
Connect scan tool.
-
Start the engine and let it run at idle.
-
Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".
-
Select "Test-ID 02: Oxygen sensor monitoring behind catalytic converter".
-
Select following Test-IDs.
-
Check the specified values at idle.
If the specified values are obtained:
-
End diagnosis and switch ignition off.
If the specified values are not obtained:
-
Remove the right vehicle floor cover - arrows -.
Checking primary voltage
-
Disconnect the brown Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector - 1 - or Oxygen
Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) - 2 -.