Eurovan L5-2369cc 2.4L DSL SOHC (AAB) Can (1993)
Vacuum Pump: Testing and Inspection
Vacuum System, Checking For Leaks
-
Pull vacuum hose off vacuum pump and seal.
-
Push positioning element diaphragm in, to do this press brake pedal down by hand to pressure point.
-
Release brake pedal.
-
Diaphragm must not move.