Eurovan L5-2369cc 2.4L DSL SOHC (AAB) Can (1993)
Heater Core Temperature Sensor / Switch: Description and Operation
Auxiliary Heater D2L, Servicing (Canada Only)
Heater-time temperature control switch -E13-, operation/function
1
-
Heater-time temperature control switch -E13-
NOTE:
-
When auxiliary heater is started, it operates at full heating capacity
-
When stable combustion is achieved, the glow plug shuts OFF and heating is regulated according to setting of temperature control switch
-
If inside temperature is lower than the selected temperature, heater will operate at 100% capacity
-
If inside temperature exceeds the selected temperature, fuel pump -G23- is switched OFF
2
-
Heater/heat output switch -E16-
Switch Position
Function
Left
Fresh air
Middle
OFF
Right
Heated air
3
-
Heater ON light -K89-, green
Indicates heater is ON
Goes out during after run
Varies in brightness: Bright - full heating power Faint - low heating power, fresh air mode
4
-
Heater malfunction light -K88-, red
Flashes during interference (overheating), switches off after fault eliminated by switching off and switching on again.