Eurovan L5-2369cc 2.4L DSL SOHC (AAB) Can (1993)
-
Reset "start of injection" a second time, take deviation into account
Example:
First value
1.00 mm
-
Checked value
0.93 mm
=
Deviation
0.07 mm
Value for second adjustment
1.07 mm
-
Hold injection pump drive sprocket using 3036 counter-hold tool after second adjustment and tighten
^
100 Nm (74 ft lb)
-
Install valve cover and toothed belt guard
-
Install power steering pump V-belt and adjust
-
Install generator V-belt and adjust
-
Install sound dampener
-
Install radiator/lock carrier