Battery: Service and Repair
Battery, Charging

Battery Charger, Connecting Safety Precautions

Battery, Charging

WARNING! Danger of explosion!

-

Batteries produce explosive gasses while being charged.

-

Keep open flames and sparks away and DO NOT smoke near batteries.

-

The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.

-

Battery cell caps must NOT be removed while charging.

-

"Boosting" a sulfated battery a high charging rate can cause an explosion.

-

Ensure that battery is charged in a well ventilated area.

-

Precision tools must not be kept in the same room where batteries are being charged. Tools may corrode due to chemical reaction.

Special tools, testers and auxiliary items

-

Battery charger: Christie Automotive 400 QDD or equivalent.

Battery With Removable Caps

Requirement

-

Temperature of battery must not be less than 10 °C (50 °F)

Tools required

-

Battery charger: Christie Automotive Model 400 QDD or equivalent

NOTES:

-

Follow battery charger manufacturer's instructions

-

Before testing a battery that has been charged, load battery with 15 amps for 1 minute to remove surface charge

WARNING!

-

Gases given oft during charging are explosive. DO NOT smoke in rooms containing a charging battery, or have bare light bulbs or any other
source of sparks or flame.

-

Battery charger MUST be turned oft when connecting or disconnecting cables on battery,

-

"Boosting" a sulfated battery at a high charging rate can cause an explosion!

Battery with removable caps

Remove cell caps while charging. If water is added, fast-charge battery for a few minutes after battery begins gassing (boiling).

Slow-charging rate should be approximately 10% of battery capacity (example: with a 45 Amp-hour battery, charging current should be about 4.5 A).

Fast-charging rate should be approximately 80-90% of battery capacity.

CAUTION!

-

Batteries may be damaged by fast-charging. It should be used only as a last alternative, when slow charging is not possible.

-

DO NOT allow battery charging voltage to exceed 17 Volts.

-

If battery begins gassing (boiling) violently when charging, REDUCE charging rate.

-

DO NOT disconnect the battery while the engine is running.

-

Charge battery according to following table:

Specific gravity

Fast charge up to

1.150 or less

1 hour

1.150 to 1.175

3/4 hour

1.175 to 1.200

1/2 hour

1.200 to 1.225

1/4 hour

above 1.225

slow charge ONLY to 1.250-1.280

Sealed Batteries

Requirement

-

Temperature of battery must not be less than 10 °C (50 °F)

Starting and Charging|Removal and Installation|Page 2261 > < Starting and Charging|Removal and Installation|Page 2259