Heater Control Valve Cable: Service and Repair
Heating & Ventilation Cables, Installing And Adjusting
Heater control valve cable
NOTE:
-
Attach cables before installing controls.
-
Place outer cable against stops on controls and secure.
-
Defroster and footwell flap cables are self-adjusting. Adjust by turning air distribution knob fully from stop to stop.
-
Adjust cable on regulating valve with controls installed.
Cables, installing
Heater control valve cable
(Identification: red/white)
-
Turn heater control valve knob fully to left stop.
-
Connect heater control valve cable -arrow-.
-
Secure cable to controls -1- with clip.