Eurovan V6-2.8L (AXK) (2001)
-
Using adapter cables from VAG1594 connector test kit, connect multimeter once each between connector terminal 7 + vehicle Ground (GND) and
connector terminal 8 + vehicle Ground (GND).
-
Operate starter and the test voltage supply for fuel injectors.
Specification: 11 to 15 V
If specified values are not obtained:
-
Check wire connection from terminal 7 and from terminal 8 to Fuel Pump (FP) relay according to wiring diagram.
Checking activation
-
Using adapter cables from the VAG1594 connector test kit, connect VAG1527 voltage tester to disconnected 10-pin connector between terminal 1
+ 7 for activation of fuel injector, cyl. 1.
-
Operate starter and then test voltage supply for fuel injector of cylinder 1. LED must flicker
-
Repeat test at fuel injectors 2 through 6
terminal 2 + 7 for activation of fuel injector, cyl. 2
terminal 3 + 7 for activation of fuel injector, cyl. 3
terminal 4 + 7 for activation of fuel injector, cyl. 4
terminal 5 + 7 for activation of fuel injector, cyl. 5
terminal 6+ 7 for activation of fuel injector, cyl. 6
If LED does not flicker:
-
Switch ignition off.