Use adapter cables from VAG1594 to connect multimeter to terminals 3 + 4 (Motronic ECM connector) for voltage measurement.

-

Start engine and measure primary voltage. Specification: 0.40 to 0.50 volts

-

Switch ignition off.

If specified value is not obtained:

-

Check wires between test box and 4-pin connector to Motronic control module for open circuit according to wiring diagram.

Terminal 3 + socket 68
Terminal 4 + socket 69

Wire resistance: max: 1.5 Ohms

If specified value is obtained:

-

Replace oxygen sensor behind Three Way Catalytic (TWC) Converter.

If no malfunctions are found in wires:

-

Replace Engine Control Module (ECM).

-

Check DTC memory, repair any malfunctions and then erase DTC memory.

-

Read readiness code. If DTC memory was erased or Engine Control Module (ECM) was disconnected from continuous B+ supply, readiness code
must be re-generated. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes

Heater Check

Oxygen Sensor Heater For Heated Oxygen Sensor (HO2S) After Three Way Catalytic Converter (TWC), Checking

NOTE:

-

Vehicle must be raised before connector to oxygen sensor is accessible.

-

When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.