volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Temp Regulator Flap Motor End Position, Checking and Adjusting|Page 3671 > < Air Door Actuator / Motor, HVAC|Locations
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Temp Regulator Flap Motor End Position, Checking and Adjusting

Temperature Regulator Flap Motor -V68- End Position, Checking And Adjusting

-

Remove footwell vent console and footwell trim 

-

Disconnect 5-pin connector T5 for -V68- at heated evaporator housing. 

-

Connect appropriate cables from adapter kit VW 1594 or VAG 1594 A to terminals 4 and 5. 

-

Connect to 12V supply. Direction of flap motor rotation can be changed by reversing polarity of voltage supply. 

-

Operate temperature flap -2- with flap motor -1- from fresh air end position -3- to heater end position -4-. 

-

Check if temperature flap lever -2- reaches stop at end position. If necessary, adjust length of connecting rod -5- with temperature flap -2- on stop. 

Checking:

By reversing polarity of 12V supply, flap motor must move fully to both end positions.

Temp Regulator Flap Motor End Position, Checking and Adjusting|Page 3671 > < Air Door Actuator / Motor, HVAC|Locations