Check wires to 4-pin connector for shorting to one another.
terminal 4 + socket 58 
-

specification: infinity Ohms

-

Check shielding for short to sensor wiring.
terminal 4 + socket 56
terminal 3 + socket 56
-

specification: infinity Ohms

If wiring OK.

-

Replace Engine Control Module -J220-.

-

Perform Basic setting.

-

Read-out Readiness code. Refer to Monitors, Trip and/or Drive Cycle (Readiness Codes)/Readiness Code Checking. See: Computers and Control
Systems/Testing and Inspection 

If DTC memory was erased:

-

Create Readiness code. Refer to Monitors, Trip and/or Drive Cycle (Readiness Codes)/Readiness Code Generating See: Computers and Control
Systems/Testing and Inspection 

Heater Check

Oxygen Sensor Heating (After CAT), Checking

Special tools and equipment

-

VAG 1551/1552 Scan Tool using VAG 1551/3 adapter cable

-

VAG 1598/18 Test Box

-

Fluke 83 multimeter (or equivalent)

-

VW 1594 Adapter kit

-

Wiring diagram

Requirement

-

Fuse 18 OK

Test sequence

-

Connect VAG 1551 (VAG 1552) Scan Tool. Refer to Scan Tool Testing/VAG 1551 Scan Tool. See: Computers and Control Systems/Testing and
Inspection 

-

With engine idling, press buttons -0- and -1- to select "Engine electronics" address word 01.

Display will appear as shown

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -8- to select "Read measuring value block" function 08.

-

Press -Q- button to enter selection.

Display will appear as shown