Check wires to 4-pin connector for shorting to one another.
terminal 4 + socket 58
-
specification: infinity Ohms
-
Check shielding for short to sensor wiring.
terminal 4 + socket 56
terminal 3 + socket 56
-
specification: infinity Ohms
If wiring OK.
-
Replace Engine Control Module -J220-.
-
Perform Basic setting.
-
Read-out Readiness code. Refer to Monitors, Trip and/or Drive Cycle (Readiness Codes)/Readiness Code Checking. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection
If DTC memory was erased:
-
Create Readiness code. Refer to Monitors, Trip and/or Drive Cycle (Readiness Codes)/Readiness Code Generating See: Powertrain
Management/Computers and Control Systems/Testing and Inspection
Heater Check
Oxygen Sensor Heating (After CAT), Checking
Special tools and equipment
-
VAG 1551/1552 Scan Tool using VAG 1551/3 adapter cable
-
VAG 1598/18 Test Box
-
Fluke 83 multimeter (or equivalent)
-
VW 1594 Adapter kit
-
Wiring diagram
Requirement
-
Fuse 18 OK
Test sequence
-
Connect VAG 1551 (VAG 1552) Scan Tool. Refer to Scan Tool Testing/VAG 1551 Scan Tool. See: Powertrain Management/Computers and
Control Systems/Testing and Inspection
-
With engine idling, press buttons -0- and -1- to select "Engine electronics" address word 01.
Display will appear as shown
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -8- to select "Read measuring value block" function 08.
-
Press -Q- button to enter selection.
Display will appear as shown