volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3101 > < Initial Inspection and Diagnostic Overview|Page 3099
Page 4
background image

-

Review noted values and determine variations in specific gravity between cells (if any).

Variations in specific gravity between cells

NOTE:

-

The maximum allowable variation range in specific gravity between cells must not be greater than 0.04 kg/cubic dm.

-

Electrolyte density must be at least 1.24 kg/cubic dm.

Example of unacceptable variations in specific gravity:

Variation range in specific gravity in Example 1, cell 4 (1.10), as well as Example 2, cell 4 (1.14) and cell 5 (1.18) are unacceptable.

Batteries shown in examples are no longer usable and must be discarded.

The following specific gravity values must be attained:

Initial Inspection and Diagnostic Overview|Page 3101 > < Initial Inspection and Diagnostic Overview|Page 3099