Store modified value?

-

Press -Q- button to confirm input. 

Indicated on display:

Channel 1 adaptation 3

->

Modified value has been stored

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 6.

NOTE:  The "End Output" function only ends the storage procedure in the control module for anti-theft immobilizer -J362- but not the adaptation of
ignition keys.

-

Insert the next ignition key into ignition lock and switch on ignition for at least 1 second.

-

Repeat procedure until all keys have been adapted.

NOTE:

-

The adaptation of ignition keys is automatically terminated after 60 seconds. Time is not counted when ignition is switched off.

-

All ignition keys adapted before termination remain valid.

-

Following termination, it is not possible to re-adapt all ignition keys unless the "Login procedure" function is called up again.

-

All ignition keys, including keys that were adapted before termination, must be re-adapted.

-

Select "Check DTC memory", function 02.

-

Erase DTC entries "Key programming incorrect, adaptation limit exceeded" using function 05.

-

Check DTC memory again.

-

If there are no DTC's stored, then key adaptation was completed successfully.