Eurovan MV V6-2.8L (AXK) (2002)
Canister Purge Control Valve: Testing and Inspection
Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-, Checking
Solenoid valve is closed when no voltage is present.
Checking activation:
Special tools and equipment
-
VAG1551 scan tool (or VAG1552 mobile scan tool) with VAG1551/3B cable
Test requirements
-
All fuses must be OK.
-
Coolant temperature must be at least 80 °C, See Display group 04, display field 3
-
No DTCs in DTC memory
Function test
-
Connect VAG 1551 scan tool (VAG1552). Start engine and select the Engine Control Module (ECM) using address word 01. Connecting scan
tool and selecting Engine Control Module (ECM):
Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -8- to select "Read measuring value block" function 08. Press -Q- button to confirm input.
Indicated on display: