Display Group 62
-
Check throttle angle of angle sensor -1- for throttle drive (power accelerator actuation) -G188- at idle stop in display field 2.
-
Press gas pedal slowly until it reaches Wide Open Throttle (WOT) position, and observe angle display in display fields 1 and 2:
Percent indication in display field 1 must rise uniformly. In the process, the tolerance range of 3 to 93% is not always used completely.
Percent indication in display field 2 must decrease uniformly. In the process, the tolerance range of 97 to 3% is not always used completely.
NOTE:
-
The value indicated in display field 1 increases, but the value indicated in display field 2 decreases, because the potentiometers (angle sensors) in
the throttle valve control module run in opposite directions.
-
This means that the voltage tap of angle sensor 1 runs from 0 to 5 volts. (The more the throttle valve is opened, the larger the voltage; percent
indication climbs).
-
The voltage tap of angle sensor 2 runs from 5 to 0 volts. (The more the throttle valve is opened, the lower the voltage; the percentage decreases).
If specified values are obtained:
-
Press the -> button.
-
Press buttons -0- and -6- to select "End Output" function 06. Press -Q- button to confirm input.
-
Switch ignition off.
Continuation