GLI L4-2.0L Turbo (CCTA) (2008)
Oxygen Sensor: Testing and Inspection
Oxygen Sensor Regulation Behind Catalytic Converter, Checking
Diagnostic Procedures
Oxygen Sensor Regulation Behind Catalytic Converter, Checking
‹› Vehicle must be raised before the electrical connector for the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) is
accessible.
‹› When servicing terminals 3 and 4 in the electrical harness connector of the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC)
(G130), use only gold-plated terminals.
Special tools, testers and auxiliary items required
‹› multimeter.
‹› Wiring diagram.
Test requirements
‹› The Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) fuse Ok.
‹› Oxygen Sensor (O2S) 1 (behind Three Way Catalytic Converter (TWC) Heater (G130) OK.
‹› Battery voltage at least 12.5 volts.
‹› All electrical consumers such as, lights and rear window defroster, switched off.
‹› Vehicles with automatic transmission, selector lever in position " P" or "N".
‹› A/C switched off.
‹› Ground (GND) connections between engine/transmission/chassis OK.
‹› Exhaust system between catalytic converter and cylinder head properly sealed.
‹› Coolant Temperature at least 80 °C.
Test procedure
-
Perform a preliminary check to verify the customers complaint. Refer to --> [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check
Start diagnosis
-
Connect scan tool.