Preparing new window without precoating for glazing > < Side window
Gaps for side window
Gaps for side window
A gap of 5..6 mm between top edge of window and window flange on side panel must be adhered to when fitting a side window.
Reason: This distance is required to fit the roof mounting system.
The rest of the adhesive sequence remains unchanged.
   