| Close shutoff valve of K-Jetronic pressure tester -V.A.G 1318- (lever across direction of flow, position -B-). |
–
| Operate remote control at short intervals until a pressure of approx. 3 bar has built up. |
WARNING Danger of spray when opening shutoff valve. Hold container in front of free connection of K-Jetronic pressure tester -V.A.G 1318-. |
|
–
| If pressure builds up too high, relieve excess pressure by carefully opening shutoff valve. |
–
| Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 2,5 bar. |
If the pressure drops further: |
–
| Check line connections for leaks. |
If no fault in lines is detected: |
–
| Fuel pump -G23- defective, renew fuel delivery unit → Chapter. |
|
|
|