| Detach pressure hose to combination valve at connection -arrow- and blow in softly. Combination valve must be closed. |
–
| Operate hand vacuum pump -VAS 6213-. Combination valve must open. |
If the combination valve does not open, or is constantly open: |
–
| Renew combination valve → Item. |
|
|
|