The converter is correctly installed when the value of dimension -a- between screw flange of gearbox housing and contact surface of stud bolts of torque converter is |
t
| 21 mm in 4-cylinder engines |
t
| 17 mm in 5 and 6-cylinder engines |
–
| It is essential to make sure that dimension -a- is maintained during further assembly. The converter is not allowed to slip forwards. |
|
|
|