Fault table
Fault table
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00258
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 1 -N88-
|
|
Solenoid valve 1 -N88- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
00260
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 2 -N89-
|
|
Solenoid valve 2 -N89- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00262
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 3 -N90-
|
|
Solenoid valve 3 -N90- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
00264
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 4 -N91-
|
|
Solenoid valve 4 -N91- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00266
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 5 -N92-
|
|
Solenoid valve 5 -N92- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
00268
|
|
Wiring open or short circuit
|
- Check wiring and connections according to current flow diagram2)
|
Solenoid valve 6 -N93-
|
|
Solenoid valve 6 -N93- defective
|
- Read measured value block
; display group number 002
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00281
|
|
Wiring open circuit
|
|
Road speed sender -G68-
No signal
|
|
Road speed sender -G68- defective
|
- Read measured value block
; display group number 001
Check wiring and connections using current flow diagram2)
|
00293
Multi-function switch
-F125-
|
|
Wiring open circuit
|
- First check multi-function switch connector for contact corrosion or water ingress, renew if necessary
|
Undefined switch condition1)
No signal1)
|
|
Multi-function switch -F125- defective
|
- Read measured value block
; display group number 001
|
00296
Kickdown switch
Implausible signal
|
|
Signal is sent continually from EPC although accelerator pedal is not depressed
|
- Read measured value block
; display group number 004
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearboxand solenoid valve wiring loom.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00300
|
|
Wiring open circuit
|
- Check wiring and connections according to current flow diagram2)
|
Gearbox oil temperature sender -G93-1)
|
|
Gearbox oil temperature sender -G93- defective
|
- Read measured value block
; Display group number 002
|
Open/short circuit to positive
|
|
-
|
1)
A faulty ATF temperature sender is indicated.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00347
|
|
Wiring open or short circuit
|
- Check wiring and connections using current flow diagram
|
Solenoid valve 8 -N281-
|
|
Solenoid valve 8 -N281- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
00348
|
|
Wiring open or short circuit
|
- Check wiring and connections using current flow diagram2)
|
Solenoid valve 9 -N282-
|
|
Solenoid valve 9 -N282- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00349
|
|
Wiring open or short circuit
|
- Check wiring and connections using current flow diagram2)
|
Solenoid valve 10 -N283-
|
|
Solenoid valve 10 -N283- defective
|
- Read measured value block
; display group number 004
|
Short to earth1)
Open circuit/short to earth1)
|
|
|
00350
|
|
Wiring open circuit
|
- Check wiring and connections using current flow diagram2)
|
Earth return wire, modulation valve
Output does not switch/short to positive
|
Control unit -J217- defective
|
- Renew control unit
|
1)
One of these displays appears in addition to relevant component.
2)
First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the connection on top of gearbox and solenoid valve wiring loom.
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00351
|
|
Wiring open or short circuit
|
- Check wiring and connections using current flow diagram1)
|
Intermediate shaft speed sender -G265-
No signal
|
|
Intermediate shaft speed sender -G265- defective
|
- Perform electrical check =>from page 01-61
|
00529
Speed information missing
No signal
|
|
Engine control unit notes that signal is faulty and sends it into the data bus
|
- If in additional faults:
01312 or 01314
are displayed, these are to rectified first
Read measured value block
; Display group number 003
Check wiring and connections using current flow diagram
|
00532
|
|
Battery defective
|
- Test battery voltage
|
Supply voltage
|
|
Insufficient system voltage for valves
|
- Read measured value block
; display group number 002
|
1)
First check connections for contact corrosion or water ingress and renew if necessary. Pay particular attention to the connections on the gearbox.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
00652
Gear monitoring
|
|
Electrical/hydraulic fault
Clutch or valve chest defective
|
- Read measured value block
; display group number 004 and establish by driving in which gear the fault occurs
|
Implausible signal1)
Mechanical fault1)
|
|
|
|
00777
|
|
- Check engine control unit
|
Accelerator pedal position sender -G79-
No signal
|
|
Engine control unit notes that signal is faulty and then sends it into data bus
|
- Read measured value block
; Display group number 002
Check wiring and connectors using current flow diagram
|
01045
Tiptronic switch -F189-
Implausible signal
|
|
Wiring open circuit
Tiptronic switch -F189- defective
|
- Check wiring and connections using current flow diagram
Read measured value block
|
1)
One of these displays appears in addition to relevant component.
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
01166
Engine torque signal
|
|
Fault of engine or its components, e.g. EPC
Engine control unit incorrectly coded
|
- If additionally the faults:
01312 or 01314
are displayed, these must be rectified first
Check wiring and connections using current flow diagram, incl. data bus wiring
|
No signal1)
Implausible signal1)
Signal outside tolerance1)
|
|
Engine control unit coded incorrectly
Engine component fault e.g. EPC
|
- Check engine control unit
|
01192
|
|
|
|
Torque converter lock-up clutch
Mechanical fault1)
Defective1)
|
Lock-up clutch slips
Valve chest defective
|
- Check torque converter lock-up clutch slip
Read measured value block
; display group number 003
|
01236
|
|
|
|
Selector lever lock solenoid -N110-
Open circuit/short to earth
|
Wiring open circuit or short to earth
Selector lever lock solenoid -N110- defective
|
- Read measured value block
; display group number 004
|
1)
One of these displays appears in addition to relevant component.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
01312
|
|
|
|
Drive train data bus
defective1)
no communication1)
|
Data bus wiring/connectors defective
|
- Check data bus wiring and connectors using current flow diagram
|
01314
|
|
|
|
Engine control unit
No communication 1)
|
Data bus wiring/connectors defective
|
- Check data bus wiring and connectors using current flow diagram
|
Incorrect equipment 1)
|
Engine control unit incorrectly coded
|
Check engine control unit repair group 01 of respective engine code
|
01316
|
|
|
|
Brake control unit
No communication
|
Data bus wiring/connectors defective
|
- Check data bus wiring and connectors using current flow diagram
|
018108
|
|
Wiring open circuit
|
- Check wiring and connectors using current flow diagram
|
Brake pressure switch -F270-
Implausible signal
|
|
Switch -F270- defective
|
- Read measured value block
|
1)
One of these displays appears in addition to relevant component.
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
17101P0717
|
|
Wiring open circuit or short to earth or positive
|
- Check wiring and connectors using current flow diagram
|
Gearbox input speed sender -G182-
|
|
Screening for wiring to gearbox input speed sender -G182- defective
Gearbox input speed sender -G182- defective
|
- Read measured value block
=> Repair group 38; Removing and installing valve chest; Renewing gearbox input speed sender -G182-
|
No signal
|
|
Engine speed, gearbox speed signal defective
Multi-function switch -F125- defective
|
- Perform fault elimination according to fault codes 00529, 00297 and 00293
|
|
|
ATF level not OK
Defective converter
|
- Check ATF level
=> Repair group 37; Checking ATF level and topping up; Checking ATF level
Check stall speed
|
|
|
Clutches or brakes slipping
Sticking solenoid valve
|
- Read measured value block
; Display group number 007 and then determine during a test drive which elements are defective or which are not activated
|
|
---|
Output on printer
V.A.G 1551
|
Possible cause of fault
|
Rectifying fault
|
65535
|
|
|
- Renew control unit
|
Control unit defective
|
|
Control unit -J217- defective
|
- Initiate basic setting
|
1)
One of these displays appears in addition to relevant component.
The control unit -J217- should not be renewed
, and the system be restored to the basic setting, until the possible cause of the fault has been determined and the following faults have been rectified:
-
◆ mechanical faults
-
◆ hydraulic faults
-
◆ all affected electrical/electronic components and cable connections.
|