Checking combination valve
Checking combination valve
Test prerequisite
l  Hose connections must be free of leaks.
Test procedure
  Note
Do not use compressed air during the following check!
–  Remove engine cover.
   
–  Remove pressure hose -arrow- from secondary air pump motor -V101-.
  Note
To release, press buttons on hose coupling together.
–  Gently blow into pressure hose to combination valve, the combination valve must be closed.
–  Blow hard into pressure hose to combination valve, the combination valve must open.
If the combination valve does not open, or is constantly open:
–  Renew combination valve.
  N26-0523