Display group 004 at full throttle (road test in 3rd gear, coolant temperature not below 80 °C) > < Evaluation: Modulating piston movement sender G149 voltage display (start and stop position stops)
Display group 000 at full throttle (road test in 3rd gear, coolant temperature not below 80 °C)
Display group 000 at full throttle (road test in 3rd gear, coolant temperature not below 80 °C)
  Note
t  When testing, accelerate the vehicle at full throttle.
t  The measured values must be printed out or read (2nd person required) when the revolutions reach 3000 rpm.
   
Display group 000 for engine codes AGR, AHF, ALH, ASV (displayed values decimal)
l  Engine speed 2900...3100 rpm
Read measured value block 0▾ appears on display  
xxxxxxxxxx   
12345678910▾ display zonesSpecificationCorresponds to
          Mass of air255800…1100 mg/stroke
         Fuel temperature91…20120…80°C
        Intake manifold temperature182…5010…100°C
       Coolant temperature80…3580…110°C
      Atmospheric pressure183…224910…1110 mbar
     Intake manifold pressure179…2151850…2250 mbar
    Quantity injected199…21439.8…42.8 mg/stroke
   Accelerator pedal position255100 %
  Commencement of injection137…2158…14° BTDC
 Engine speed138…1482900…3100 rpm

   
Display group 000 for engine codes AGP, AQM (displayed values decimal)
l  Engine speed 2900...3100 rpm
Read measured value block 0▾ appears on display  
xxxxxxxxxx   
12345678910▾ display zonesSpecificationCorresponds to
          Mass of airIgnoreIgnore
         Fuel temperature91…20120…80°C
        Intake air temperature182…5010…100°C
       Coolant temperature80…3580…110°C
      Atmospheric pressure181…222900…1100 mbar
     Intake manifold pressureIgnore---
    Quantity injected125…14025.0…28.0 mg/stroke
   Accelerator pedal position255100 %
  Commencement of injection113…1636...10° BTDC
 Engine speed138…1482900…3100 rpm

   

Display group 004 at full throttle (road test in 3rd gear, coolant temperature not below 80 °C) > < Evaluation: Modulating piston movement sender G149 voltage display (start and stop position stops)