Golf Mk4
Display group 19 with ignition on |
Display group 019 -Quantity adjuster | ||||||
Read measured value block 19 | → | ▾ Indicated on display | ||||
x.xxx V | x.xxx V | |||||
1 | 2 | 3 | 4 | ▾ Display zones | Specification | Evaluation |
No display | --- | |||||
No display | --- | |||||
Voltage from modulating piston travel sender -G149- (start limit stop) | 4.150…4.740 V | → Chapter | ||||
Voltage from modulating piston travel sender -G149- (stop limit stop) | 0.500…0.970 V | → Chapter |