Do not additionally oil or grease the oil seal sealing lip.
t
If an aluminium sealing flange is installed in place of a plate sealing flange, insert centring pins and use longer bolts → ETKA (Electronic parts catalogue).
–
Clean sealing surfaces. They must be free of oil and grease.
–
Remove oil residue from end of crankshaft journal using clean cloth.
–
Assemble fitting tool sleeves -T10122/1- and -T10122/2-.
–
Push sealing flange -A- with outer side onto fitting tool sleeves.
–
Separate fitting sleeves.
–
Set sealing flange -A- with fitting tool sleeve -T10122/2- on crankshaft and push sealing flange onto crankshaft journal.