| Pull off breather line -1-. To do this, press release button. |
–
| Then connect hand vacuum pump -VAS 6213- using adapter set -V.A.G 1318/17- to the activated charcoal filter line. |
–
| Operate hand vacuum pump -VAS 6213- several times. Vacuum must not build up. |
–
| Check breather hose → Item on activated charcoal filter for soiling and clean if necessary. |
If vacuum does not build up. |
–
| Hold breather connection → Item shut and operate vacuum pump again several times. A vacuum must build up. |
If vacuum does not build up. |
–
| Renew activated charcoal filter. |
|
|
|