| Then connect hand vacuum pump -VAS 6213--1- to breather line -2- to activated charcoal filter as shown. |
–
| Operate hand vacuum pump -VAS 6213- several times. Vacuum must not build up. |
–
| Check breather hole on activated charcoal filter → Item for soiling and clean if necessary. |
If vacuum does not build up: |
|
|
|