Golf L4-1.9L DSL Turbo (AHU) (1997)
Rapid data transfer HELP
select function XX
-
Press -0- and -8- buttons to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input
Display will appear as shown:
Read measuring value block HELP
Input display group number XX
-
Press -0-, -0- and -2- buttons to input display group 02 (002), and press -Q- button to confirm input
Display will appear as shown:
Read measuring value block 2 ->
0 rpm 0.0% 0 1 0 18.4°C
Check throttle position in display field 2
Accelerator pedal not depressed (at rest position)
Specification: 0.0%
-
Fully (slowly) depress accelerator pedal while watching value in display field 2
Display will appear as shown:
Read measuring value block 2 ->
0 rpm 100% 0 1 0 18.4°C
Throttle position value must increase continuously and then display 100% just before the Wide Open Throttle stop
If necessary, adjust throttle position as follows
Turn adjustment screw -7- until Closed Throttle Position (CTP) display shows 0.0%
Depress accelerator pedal to point just before Wide Open Throttle (WOT)
Display must show 100%.
Check and erase DTC memory
Recreate readiness code