- Commercially available hydrometer

- Cleaning cloths

WARNING!

- When using sulfuric acid it is absolutely necessary that the accident prevention procedures are observed. Suitable protective clothing must be worn.

- When disposing of batteries it is absolutely necessary that the disposal procedures for batteries and sulfuric acid are observed.

The electrolyte specific gravity test in conjunction with the battery load test provides specific information of the battery condition.

The battery acid temperature must be at least 10°C.

The electrolyte density must be checked in all battery cells as follows:

- Switch ignition off.

- Remove all battery plugs (battery cell sealing plugs).

- Immerse end of hydrometer in cell and extract sufficient electrolyte to allow indicator to float freely in the electrolyte.

The denser the extracted electrolyte the higher the indicator floats.

The density in kg/dm3 can be read off the scale of the hydrometer (specific density of electrolyte).