volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Engine Controls - Silicone Sealer/Lubricant Precautions|Page 1865 > < Engine Controls - Silicone Sealer/Lubricant Precautions
Page 1
background image

Air Flow Meter/Sensor: Testing and Inspection

Exhaust Gas Recirculation and Mass Air Flow sensor function can be checked via Output Diagnostic Test Mode (DTM) Function 03 and by also
calling-up measuring value block 03 (Function 08). To do this, activate the Output DTM component: EGR Vacuum Regulator Solenoid valve N18 and
then after exiting the Output Diagnostic Test Mode, check N18 via the -C- button.
By using this sequence, the EGR valve continues to be pulsed so that with the help of measuring value block 03 (display zone 3) the extreme values for
the EGR valve/Mass Air Flow sensor can be displayed.

Special Tools, Testers And Auxiliary Items:

-

VAG 1551/1552 Scan Tool with VAG 1551/3 adaptor cable

-

VAG 1595/15 Test Box

-

Fluke 53 multimeter (or equivalent)

-

WV 1594 adaptor kit

-

Wiring diagram

Test Sequence:

-

Connect VAG 1551/1552 Scan Tool

-

Start engine and let idle

-

Press 0 and 1 buttons to select address word o1 "engine electronics"
Display will appear as shown:

Rapid data transfer HELP
select function XX

-

Press 0 and 3 buttons to select Function 03 "Output Diagnostic Test Mode"

-

Press Q button to enter input
Display will appear as shown:

Rapid data transfer Q
03 Output Diagnostic Test Mode

NOTE:  Individual DTM components are activated for 30 seconds. Various work sequences must be carried out with the Scan Tool within this
period as well as reading the displayed values. Read over the following work sequence first to familiarize yourself with the procedure.

Display will appear as shown:

Output Diagnostic Test Mode ->
start of injection valve - N108

-

Press -> button
Display will appear as shown:

Output Diagnostic Test Mode ->
Exhaust gas recirculation valve - N18

-

Press C button

-

Press 0 and 8 buttons to select Function 08 "Read measuring value block"

-

Press Q button to enter input
Display will appear as shown:

Read measuring value block HELP
Input display group number XXX

-

Press 0, 0 and 3 buttons to select "display group 3"

-

Press Q button to enter input
Display will appear as shown:

Read measuring value block 3 ->
840 rpm 272 mg/H 268 mg/H 54%

-

Indicated on display

NOTE:  The values in display zones 3 and 4 must fluctuate within the following control mode:
-

Specification display zone 3
Lower range: 230 to 310 mg/stroke.
Upper range: 360 to 480 mg/stroke.

Engine Controls - Silicone Sealer/Lubricant Precautions|Page 1865 > < Engine Controls - Silicone Sealer/Lubricant Precautions