volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

EGR Wide Open Throttle Valve|Testing and Inspection|Page 2043 > < Engine Code AAZ|Page 2039
Page 1
background image

EGR Wide Open Throttle Valve: Testing and Inspection

Special Tools, Testers And Auxiliary Items:

-

Fluke 83 multimeter (or equivalent)

-

VW1594 connector test kit

-

12 mm hex drive and glow plug or equivalent spacer 

Test Sequence:

-

Disconnect 2-pin harness connector -1- from EGR part throttle switch -F166-.

-

Measure resistance between EGR part throttle switch terminals using multimeter.
-

Switch open (pump lever on idle speed stop): infinite ohms.

-

Switch closed (pump lever toward WOT): 0 ohms.

Adjusting:

NOTE:  The EGR part throttle switch, switch points are set by the manufacturer on a test stand and must not be altered.

Adjust new switches as follows:

-

Operate injection pump lever and clamp 12 mm hex drive of glow plug between stop (arrow-1-) and lower edge of operating lever (arrow -2-).

-

Press operating lever securely against glow plug (arrow -3-). In this position, adjust EGR part throttle switch by sliding unit in elongated holes
until switch point (switch clicks) is just behind highest point on curved plate (arrow -4-).

NOTE:  The upper EGR part throttle switch cover is shown removed to make the illustrated switch point more clear.

EGR Wide Open Throttle Valve|Testing and Inspection|Page 2043 > < Engine Code AAZ|Page 2039