Golf L4-2.0L (ABA) (1996)
Battery: All Technical Service Bulletins
Battery - Low State of Charge
Group: 27
Number: 97-03
Date: Sept. 17, 1997
Subject:
Generator B+ Terminal, Connection
Model(s):
Golf, GTI, Jetta
1994 -->VIN TM037600
Supersedes T.B. Group 27 Number 95-04 dated Apr. 18, 1995
Condition
Battery low state of charge can be caused by poor or intermittent electrical contact between wiring harness eyelet connector and Generator B+ terminal.
Service
-
Obtain radio code.
-
Disconnect battery ground (GND).
-
Remove eyelet terminal from Generator B+ stud.
-
Remove approximately 6 mm of the eyelet terminal insulation.
-
Clean any residue or corrosion from eyelet terminal.
-
Apply Stabilant 22A Part No. ZVW 186 001 to eyelet terminal.
-
Reinstall eyelet terminal on Generator B+ stud.
^
Tightening torque: 13 Nm (10 ft. lb)
-
Reconnect Battery (GND).
-
Recode radio.